LCA: EE 110: Commissioning and Lighting Controls

Content
29 modules

Instructor
NEMA Academy

Price
$5.00

Description

In an ideal project, the building owner clearly defines the project goals, the design team develops an appropriate design, contractors install the system according to the design documents, and the completed building performs as intended.

In practice, however, many factors can lead to performance problems:

  • Owner expectations may be unclear or poorly documented.
  • Design documents may not clearly communicate design intent.
  • Incorrect equipment is supplied or substituted during construction.
  • Systems may be installed or programmed incorrectly.
  • Building personnel may not understand how systems should function.

Project commissioning, a systematic process used throughout a project to verify and document that building systems perform according to the owner’s project requirements and design intent, addresses these challenges.

For lighting and lighting controls, commissioning ensures that the installed system:

  • Operates according to the intended control sequences.
  • Represents the intent of the Construction Documents
  • Integrates seamlessly with other building systems.
  • Provides the expected lighting performance and energy savings.
  • May also verify compliance with applicable energy codes and standards.

Commissioning begins during the pre-design phase and may continue following a period of building occupancy to confirm that the system performs as intended.

Objectives

By the end of this course, you will be able to:

  • Understand the roles and responsibilities of the commissioning team.
  • Describe the key documents used during commissioning.
  • Identify commissioning activities during each project phase.

Comply with mandatory commissioning, verification, and functional testing requirements in commercial building energy codes.

Certificate

By completing/passing this course, you will attain the certificate EE110: Commissioning and Lighting Controls Certificate

Learning credits

AIA
2.0
CEU
0.2
LEU
2.0
NLCAA
10.0

Badges

{{ badge.name }}

{{ vm.helper.t('lup.gamification.value') }}

{{ badge.points }} {{ vm.helper.t('lup.gamification.points') }}

{{ vm.helper.t('lup.gamification.achieved_for_selected_score_and_over')}}

{{ badge.name }}

{{ vm.helper.t('lup.gamification.value')}}

{{ badge.points }} {{ vm.helper.t('lup.gamification.points') }}

{{ vm.helper.t('lup.gamification.achieved') }}

{{ vm.helper.t('lup.gamification.learning_awards.on_course_completion') }}
1.
INTRODUCTION
{{ vm.helper.t('reports.module') }}
2.
BENEFITS OF COMMISSIONING
{{ vm.helper.t('reports.module') }}
3.
ECONOMIC BENEFITS
{{ vm.helper.t('reports.module') }}
4.
ENERGY CODES AND STANDARDS
{{ vm.helper.t('reports.module') }}
5.
ENERGY CODE REQUIREMENTS FOR COMMISSIONING
{{ vm.helper.t('reports.module') }}
6.
COMMISSIONING GUIDELINES
{{ vm.helper.t('reports.module') }}
7.
WHAT COMMISSIONING IS NOT
{{ vm.helper.t('reports.module') }}
8.
THE COMMISSIONING PROCESS
{{ vm.helper.t('reports.module') }}
9.
PRE-DESIGN PHASE
{{ vm.helper.t('reports.module') }}
10.
ISSUES LOG
{{ vm.helper.t('reports.module') }}
11.
DESIGN PHASE
{{ vm.helper.t('reports.module') }}
12.
COMMISSIONING PROVIDER’S ROLE DURING DESIGN
{{ vm.helper.t('reports.module') }}
13.
CONSTRUCTION PHASE
{{ vm.helper.t('reports.module') }}
14.
CONTROLS EQUIPMENT CHECKLIST
{{ vm.helper.t('reports.module') }}
15.
PRE-FUNCTIONAL CHECKLIST
{{ vm.helper.t('reports.module') }}
16.
FUNCTIONAL TESTING
{{ vm.helper.t('reports.module') }}
17.
FUNCTIONAL TESTING REQUIREMENTS FOR ENERGY CODE COMPLIANCE
{{ vm.helper.t('reports.module') }}
18.
FUNCTIONAL TESTING: USER INTERFACES
{{ vm.helper.t('reports.module') }}
19.
FUNCTIONAL TESTING: AUTOMATIC CONTROLS
{{ vm.helper.t('reports.module') }}
20.
FIELD CALIBRATION
{{ vm.helper.t('reports.module') }}
21.
CASE IN POINT
{{ vm.helper.t('reports.module') }}
22.
USER TRAINING
{{ vm.helper.t('reports.module') }}
23.
TRAINING DOCUMENTATION REQUIREMENTS
{{ vm.helper.t('reports.module') }}
24.
COMMISSIONING REPORT
{{ vm.helper.t('reports.module') }}
25.
SYSTEMS MANUAL
{{ vm.helper.t('reports.module') }}
26.
POST-OCCUPANCY
{{ vm.helper.t('reports.module') }}
27.
YOU’RE FINISHED
{{ vm.helper.t('reports.module') }}
28.
EE110: COMMISSIONING AND LIGHTING CONTROLS EXAM
{{ vm.helper.t('courses.exam') }}
29.
EE110: COMMISSIONING AND LIGHTING CONTROLS SURVEY
{{ vm.helper.t('courses.survey') }}