Content
19 modules
Instructor
NEMA Academy
Price
$5.00
Description
This learning module describes popular dimming strategies and how different light sources behave when dimmed.
Objectives
By the end of this course, participants will be able to:
- Advise clients about the difference between switching, step dimming, and continuous dimming, and how LED drivers affect dimming quality and compatibility.
- Recognize and address common dimming problems.
- Utilize dimming in manual control, daylight-responsive control, lumen maintenance, institutional tuning, and demand response control strategies.
- Identify documentation and commissioning steps needed for successful dimming systems.
Certificate
By completing/passing this course, you will attain the certificate EE Lighting Controls Certificate (AIA, LEU, CALCTP, NLCAA, CEU)
Learning credits
AIA
2.0
CALCTP
10.0
CEU
0.2
LEU
2.0
NLCAA
10.0
Badges
{{ badge.name }}
{{ vm.helper.t('lup.gamification.value') }}
{{ badge.points }} {{ vm.helper.t('lup.gamification.points') }}
{{ vm.helper.t('lup.gamification.achieved_for_selected_score_and_over')}}
{{ badge.name }}
{{ vm.helper.t('lup.gamification.value')}}
{{ badge.points }} {{ vm.helper.t('lup.gamification.points') }}
{{ vm.helper.t('lup.gamification.achieved') }}
{{ vm.helper.t('lup.gamification.learning_awards.on_course_completion') }}
1.
INTRODUCTION
{{ vm.helper.t('reports.module') }}
2.
DIMMING CORE CONCEPTS
{{ vm.helper.t('reports.module') }}
3.
CODE REQUIREMENTS AFFECTING DIMMING
{{ vm.helper.t('reports.module') }}
4.
LEGACY DIMMING TECHNOLOGIES
{{ vm.helper.t('reports.module') }}
5.
HIGH-END TRIM & TASK TUNING
{{ vm.helper.t('reports.module') }}
6.
COLOR TUNING
{{ vm.helper.t('reports.module') }}
7.
LIGHT OUTPUT AND PERCEPTION
{{ vm.helper.t('reports.module') }}
8.
THE DIMMING CURVE
{{ vm.helper.t('reports.module') }}
9.
DIMMING AND LED DRIVERS
{{ vm.helper.t('reports.module') }}
10.
COMMON DIMMING CONTROL METHODS AND PROTOCOLS
{{ vm.helper.t('reports.module') }}
11.
MANUAL DIMMING APPLICATIONS
{{ vm.helper.t('reports.module') }}
12.
AUTOMATIC DIMMING APPLICATIONS
{{ vm.helper.t('reports.module') }}
13.
DESIGN BEST PRACTICES FOR DIMMING
{{ vm.helper.t('reports.module') }}
14.
COMMISSIONING AND FUNCTIONAL TESTING
{{ vm.helper.t('reports.module') }}
15.
AVOIDING DIMMING PROBLEMS
{{ vm.helper.t('reports.module') }}
16.
DOCUMENTATION DELIVERABLES
{{ vm.helper.t('reports.module') }}
17.
YOU’RE FINISHED
{{ vm.helper.t('reports.module') }}
18.
LCA: EE103: Dimming Control Part 1, Introduction to Dimming
{{ vm.helper.t('courses.exam') }}
19.
LCA: EE103: Dimming Control Part 1, Introduction to Dimming - Survey
{{ vm.helper.t('courses.survey') }}
Shopping cart
Your cart is empty