Content
28 modules
Instructor
NEMA Academy
Price
$5.00
Description
This learning module introduces commissioning, a quality assurance process that ensures installed building systems perform interactively and continuously according to owner needs and the design intent.
Certificate
By completing/passing this course, you will attain the certificate EE110: Commissioning and Lighting Controls Certificate
Learning credits
AIA
2.0
CEU
0.2
LEU
2.0
NLCAA
10.0
Badges
{{ badge.name }}
{{ vm.helper.t('lup.gamification.value') }}
{{ badge.points }} {{ vm.helper.t('lup.gamification.points') }}
{{ vm.helper.t('lup.gamification.achieved_for_selected_score_and_over')}}
{{ badge.name }}
{{ vm.helper.t('lup.gamification.value')}}
{{ badge.points }} {{ vm.helper.t('lup.gamification.points') }}
{{ vm.helper.t('lup.gamification.achieved') }}
{{ vm.helper.t('lup.gamification.learning_awards.on_course_completion') }}
1.
INTRODUCTION
{{ vm.helper.t('reports.module') }}
2.
Lecture Video
{{ vm.helper.t('reports.module') }}
3.
BENEFITS OF COMMISSIONING
{{ vm.helper.t('reports.module') }}
4.
ECONOMIC BENEFITS
{{ vm.helper.t('reports.module') }}
5.
THE COMMISSIONING PROCESS
{{ vm.helper.t('reports.module') }}
6.
ENERGY CODES AND STANDARDS
{{ vm.helper.t('reports.module') }}
7.
WHAT COMMISSIONING IS NOT
{{ vm.helper.t('reports.module') }}
8.
THE COMMISSIONING PROCESS
{{ vm.helper.t('reports.module') }}
9.
OWNER PROJECT REQUIREMENTS
{{ vm.helper.t('reports.module') }}
10.
BASIS OF DESIGN
{{ vm.helper.t('reports.module') }}
11.
DESIGN PHASE
{{ vm.helper.t('reports.module') }}
12.
PERFORMANCE TESTING
{{ vm.helper.t('reports.module') }}
13.
PERFORMANCE TESTING
{{ vm.helper.t('reports.module') }}
14.
CASE IN POINT
{{ vm.helper.t('reports.module') }}
15.
CASE IN POINT
{{ vm.helper.t('reports.module') }}
16.
EQUIPMENT VERIFICATION
{{ vm.helper.t('reports.module') }}
17.
FIELD CALIBRATION
{{ vm.helper.t('reports.module') }}
18.
FUNCTIONAL TESTING PRE-CHECKLIST
{{ vm.helper.t('reports.module') }}
19.
FUNCTIONAL TESTING: TIME-SWITCH CONTROLS
{{ vm.helper.t('reports.module') }}
20.
FUNCTIONAL TESTING: OCCUPANCY SENSORS
{{ vm.helper.t('reports.module') }}
21.
FUNCTIONAL TESTING: DAYLIGHT-RESPONSIVE CONTROLS
{{ vm.helper.t('reports.module') }}
22.
DOCUMENTATION
{{ vm.helper.t('reports.module') }}
23.
USER TRAINING
{{ vm.helper.t('reports.module') }}
24.
POST-OCCUPANCY
{{ vm.helper.t('reports.module') }}
25.
YOU’RE FINISHED
{{ vm.helper.t('reports.module') }}
26.
EE110: COMMISSIONING AND LIGHTING CONTROLS EXAM
{{ vm.helper.t('courses.exam') }}
27.
EE110: COMMISSIONING AND LIGHTING CONTROLS SURVEY
{{ vm.helper.t('courses.survey') }}
28.
Commissioning and Lighting Controls: Additional Content
{{ vm.helper.t('reports.module') }}
Shopping Cart
Your cart is empty