LCA: EE203: Lighting Controls and Commercial Building Energy Codes: 90.1-2016 and 2018 IECC

Content
31 modules

Instructor
Craig DiLouie

Price
$5.00

Description

This learning module provides general introductory knowledge about the lighting control requirements imposed by the 2016 version of ASHRAE/IES 90.1 and the 2018 version of the IECC.

Certificate

By completing/passing this course, you will attain the certificate EE Lighting Controls Certificate (AIA, LEU, CEU)

Learning credits

AIA
2.0
CEU
0.2
LEU
2.0

Badges

{{ badge.name }}

{{ vm.helper.t('lup.gamification.value') }}

{{ badge.points }} {{ vm.helper.t('lup.gamification.points') }}

{{ vm.helper.t('lup.gamification.achieved_for_selected_score_and_over')}}

{{ badge.name }}

{{ vm.helper.t('lup.gamification.value')}}

{{ badge.points }} {{ vm.helper.t('lup.gamification.points') }}

{{ vm.helper.t('lup.gamification.achieved') }}

{{ vm.helper.t('lup.gamification.learning_awards.on_course_completion') }}
1.
INTRODUCTION
{{ vm.helper.t('reports.module') }}
2.
ENERGY STANDARDS
{{ vm.helper.t('reports.module') }}
3.
LIGHTING AND CONTROL REQUIREMENTS AT A GLANCE
{{ vm.helper.t('reports.module') }}
4.
NEW VERSUS EXISTING BUILDINGS
{{ vm.helper.t('reports.module') }}
5.
GENERAL EXEMPTIONS TO LIGHTING CONTROL REQUIREMENTS
{{ vm.helper.t('reports.module') }}
6.
COMPLIANCE PATHS (IECC 2018)
{{ vm.helper.t('reports.module') }}
7.
INTERIOR SPACE CONTROLS
{{ vm.helper.t('reports.module') }}
8.
LIGHT REDUCTION SPACE CONTROL
{{ vm.helper.t('reports.module') }}
9.
AUTOMATIC SHUTOFF OF INTERIOR LIGHTING
{{ vm.helper.t('reports.module') }}
10.
OCCUPANCY-BASED AUTOMATIC SHUTOFF
{{ vm.helper.t('reports.module') }}
11.
OCCUPANCY-BASED AUTOMATIC SHUTOFF
{{ vm.helper.t('reports.module') }}
12.
OCCUPANCY SENSORS IN WAREHOUSES (IECC)
{{ vm.helper.t('reports.module') }}
13.
OCCUPANCY SENSORS IN OPEN OFFICES (IECC)
{{ vm.helper.t('reports.module') }}
14.
OCCUPANCY SENSORS FOR LIGHT REDUCTION (90.1)
{{ vm.helper.t('reports.module') }}
15.
PARKING GARAGES (90.1)
{{ vm.helper.t('reports.module') }}
16.
TIME-BASED AUTOMATIC SHUTOFF
{{ vm.helper.t('reports.module') }}
17.
DAYLIGHT-RESPONSIVE CONTROL
{{ vm.helper.t('reports.module') }}
18.
DAYLIGHT-RESPONSIVE CONTROL
{{ vm.helper.t('reports.module') }}
19.
DAYLIGHT-RESPONSIVE CONTROL
{{ vm.helper.t('reports.module') }}
20.
DAYLIGHT-RESPONSIVE CONTROL
{{ vm.helper.t('reports.module') }}
21.
OTHER SPECIFIC-APPLICATION CONTROLS
{{ vm.helper.t('reports.module') }}
22.
POWER ADJUSTMENT CREDITS (90.1)
{{ vm.helper.t('reports.module') }}
23.
ADDITIONAL ENERGY EFFICIENCY (IECC)
{{ vm.helper.t('reports.module') }}
24.
EXTERIOR LIGHTING
{{ vm.helper.t('reports.module') }}
25.
FUNCTIONAL TESTING
{{ vm.helper.t('reports.module') }}
26.
DOCUMENTATION
{{ vm.helper.t('reports.module') }}
27.
CONCLUSIONS
{{ vm.helper.t('reports.module') }}
28.
YOU’RE FINISHED
{{ vm.helper.t('reports.module') }}
29.
Lighting Controls and Commercial Building Energy Codes, Part 3: ASHRAE/IES 90.1-2016 and IECC 2018 - Additional Resources
{{ vm.helper.t('reports.module') }}
30.
EE203 Lighting Controls and Commercial Energy Codes, Part 3: 90.1-2016 and IECC 2018 Exam
{{ vm.helper.t('courses.exam') }}
31.
EE203 Lighting Controls and Commercial Energy Codes, Part 3: 90.1-2016 and IECC 2018 Survey
{{ vm.helper.t('courses.survey') }}

Shopping Cart

Your cart is empty